How To Extend the Life of A pH Meter
pH metres are instruments that are utilised in the process of determining the acidity or alkalinity of a liquid, which is also referred to as the pH level. The difference in the electrical potential between a reference electrode and a measuring electrode, both of which are submerged in the liquid being evaluated, is used to determine the results of the test. The measuring electrode is normally a glass electrode, while the reference electrode is frequently a silver/silver chloride electrode or a calomel electrode. The calomel electrode may also be used.
The measurement on the pH metre is influenced by a number of different elements, including temperature, pressure, viscosity, and the presence of other ions in the liquid being measured. As a result of this, it is essential to check that the pH metre is calibrated appropriately and that the conditions under which the readings are taken are constant and reliable.
A pH meter’s accuracy can be affected by a variety of factors. The phenomenon known as “reference poisoning,” which occurs when the reference electrode becomes polluted with substances that are not supposed to be present in the liquid being tested, is one of the most prevalent factors that leads to a test not being successful. This can result in erroneous results from the pH metre and perhaps cause damage to the sensor. It is essential to ensure that the reference electrode is kept clean at all times and is free of any impurities in order to avoid the risk of reference poisoning. In addition to this, it is essential to make use of a reference electrode that is suitable for the liquid that is under investigation.
Other reasons for an inaccurate pH reading include the following:
The glass electrode can degrade with time, which can lead to false readings. This is due to the ageing of the electrode.
Damage to the electrode may occur either as a result of direct physical contact or as a result of the electrode’s exposure to substances that are incompatible with the sensor.
Incorrect sensor calibration: If the sensor is not calibrated properly, it can result in values that are not accurate.
It is crucial to follow regular maintenance practises and make sure that the sensors are utilised in acceptable settings in order to ensure accurate pH measurements and to extend the life of the pH metre. In addition, this will ensure that the results are accurate.