Leak detection cables are sensors that can be used to detect leaks in double wall piping systems. The cables are typically made from a flexible material that can be installed around the inner wall of the piping system. They are designed to detect the presence of a liquid or gas that is leaking from the inner wall of the piping system.
Leak detection cables can be used in a variety of piping systems, including those that transport hazardous or toxic fluids. They are often used in conjunction with other leak detection systems, such as pressure monitoring systems or mass balance systems, to provide additional layers of protection against leaks.
When selecting a leak detection cable for a double wall piping system, it’s important to consider the specific characteristics of the fluid being transported, the process conditions in which the cable will be used, and the requirements of the application. It’s also important to consider the cost, maintenance requirements, and reliability of the cable. Additionally, it’s important to ensure that the cable is compatible with any other equipment or systems it will be used with.
Capacitive leak detection sensors are sensors that use capacitance, or the ability to store electrical charge, to detect leaks in double walled piping systems. The sensors consist of two electrodes, and the capacitance between the electrodes changes as the level of the fluid in the piping system changes.
Capacitive leak detection sensors can be used to detect leaks in a variety of piping systems, including those that transport hazardous or toxic fluids. They can be installed on the outside of the piping system or inside the piping system, depending on the specific application.
When selecting a capacitive leak detection sensor for a double walled piping system, it’s important to consider the specific characteristics of the fluid being transported, the process conditions in which the sensor will be used, and the requirements of the application. It’s also important to consider the accuracy and repeatability of the sensor, as well as the maintenance and calibration requirements. Additionally, it’s important to ensure that the sensor is compatible with any other equipment or systems it will be used with.
Additional types of leak detection systems that can be used for double walled piping systems:
- Acoustic leak detection systems: These systems use sensors to detect the sound of a leak in the piping system. The sensors can be placed on the outside of the pipe or installed inside the pipe, and they are sensitive to the high-frequency noise that is typically associated with a leak.
- Pressure monitoring systems: These systems use sensors to monitor the pressure of the fluid in the piping system. If the pressure drops unexpectedly, it could indicate a leak in the piping system.
- Mass balance systems: These systems use sensors to measure the mass of the fluid flowing into and out of the piping system. If the mass balance is not consistent, it could indicate a leak in the piping system.
- Thermal imaging systems: These systems use thermal cameras to detect temperature variations that could indicate a leak in the piping system.
- Tracer gas systems: These systems use a gas that is injected into the piping system and is designed to leak out if there is a hole or crack in the piping. Sensors can then be used to detect the presence of the tracer gas, which indicates a leak in the piping system.
When selecting a leak detection system for a double walled piping system, it’s important to consider the specific characteristics of the fluid being transported, the process conditions in which the system will be used, and the requirements of the application. It’s also important to consider the cost, maintenance requirements, and reliability of the system.
Learn more about leak detection sensors for double wall piping system
Please contact us to discuss your application